Now showing circuits 201-220 of 310. Sort by
parametric ideal diode 02 PUBLICby signality | updated September 17, 2012 |
|
parametric ideal diode 01 PUBLICSetting the N parameter of a diode model to a very small number produces a small forward voltage drop and so approximates an ideal diode response. by signality | updated September 17, 2012 |
|
AC analysis with multiple sources PUBLICA demonstration of how to run an AC analysis of a circuit with two AC sources. by signality | updated August 25, 2012 |
|
Multi-winding transformer 02 PUBLICA transformer model with adjustable coupling between the inductors and the leakage inductances modelled appropriately. Simulate > Time Domain > Run Time-Domain Simulation. by signality | updated August 24, 2012 behavioural-transformer coupled-inductors leakage-inductance multiwinding-transformer transformer |
|
coupled inductors 01 / transformer comparison 03 PUBLICA way to make a pair of inductors with an adjustable coupling factor. To run the simulation: Simulate > Time Domain > Run Time-Domain Simulation or F5 by signality | updated August 24, 2012 |
|
cap_loaded_opamp_01 PUBLICAn simple example of compensating a capacitively loaded opamp. Simulate > Time Domain > Run Time-Domain Simulation. by signality | updated August 23, 2012 |
|
simple class d amp 01 PUBLICA very quick and dirty Class D amp demo by signality | updated August 07, 2012 |
|
RMS Voltmeter 01 PUBLICA way to simulate a true RMS voltmeter and a true RMS ammeter. Simulate > Time Domain > Run Time-Domain Simulation by signality | updated August 06, 2012 |
|
voltage controlled SPDT switch 01 PUBLICUsing two voltage controlled switches, a buffer, an inverter and a PWS() source to make a voltage controlled SPDT switch. Simulate > Time Domain > Run Time-Domain SImulation by signality | updated August 05, 2012 |
|
Sweeping a switch parameter 01 PUBLICSweeping the ON resistance of a 'static' switch. Switch state must be set to 'closed'. Simulate > Time Domain > Run Time-Domain Simulation by signality | updated August 04, 2012 |
|
Sweeping a switch parameter 02 PUBLICSweeping the ON resistance of a 'static' switch. Switch state must be manually set to 'A' or 'B'. Simulate > Time Domain > Run Time-Domain Simulation by signality | updated August 04, 2012 |
|
P-MOSFET Buck Converter (Switching Power Supply) closed loop 01 PUBLICBasic closed loop 12V to 3V Voltage Mode Buck (step down) converter. Simulate > Time Domain > Run Time-Domain Simulation by signality | updated August 03, 2012 buck-converter power-supply smps step-down-converter switching voltage-mode |
|
PWM 01 PUBLICV(duty) sets the duty cycle of the PWM output. V(saw) is a 0 to 1V swing sawtooth and sets the PWM frequency. V(amp) sets the amplitude of the PWM output. V(offset) sets the DC offset of the PWM... by signality | updated July 28, 2012 |
|
3 phase 01 PUBLICA demonstration of single phase and 3 phase, Star and Delta connected, mains. Simulate > Time Domain > Run Time-Domain Simulation by signality | updated July 24, 2012 |
|
Open Collector Comparator using Switch 02 - adding external hysteresis PUBLICOpen Collector Comparator An extension of the original circuit by Carl Sawtell. by signality | updated July 17, 2012 |
|
Understanding the CL transformer symbol 03 PUBLICWhat happens when the CL transformer symbol is flipped horizontally. by signality | updated July 17, 2012 |
|
behavioural open collector/drain comparator 01 PUBLICA behavioural open collector/drain comparator with a 10 Ohm pulldown resistance. Simulate > Time Domain > Run Time-Domain SImulation by signality | updated July 17, 2012 |
|
spark gap 01 PUBLICBehavioural spark gap. Adapted for CL from analogspiceman's LTspice circuit: http://ltwiki.org/files/adventures_with_analog/SparkGap.asc by signality | updated July 13, 2012 |
|
Measuring capacitance using a ramped voltage source PUBLICMeasuring capacitance using a ramped voltage source. The vertical axis is scaled to the capacitance value in Farads. Simulate > Time Domain > Run Time-Domain Simulation by signality | updated July 12, 2012 |
|
Measuring inductance using a ramped current source PUBLICMeasuring inductance using a ramped current source. The vertical axis is scaled to the inductance value in Henrys. Simulate > Time Domain > Run Time-Domain Simulation by signality | updated July 12, 2012 |